1. Define the question and trace the evidence
Turn a broad carbon question into one bounded electricity activity with auditable evidence.
Suggested first pass: forty-five minutes, including the worked example, exercise and self-check.
Start with the question your result can actually answer: what emissions are associated with this facility's documented purchased electricity for this month under this stated factor? A carbon number without facility, period, activity and method is hard to interpret. BOUNDARY-01 deliberately covers less than a complete business inventory. A single electricity result cannot establish product emissions, company-wide completeness, regulatory compliance or carbon neutrality. Record exclusions before calculating, rather than shrinking the boundary after seeing a result.
In worked W, the activity is Training-West's January 2027 electricity consumption. W-BILL-101 gives 12 MWh and W-METER-101 supplies an independent-looking corroborating log: 92,000 minus 80,000 kWh. These are fictional records, so an exercise can test whether they agree but cannot prove a real supplier issued them. W-IMPORT-101 is the same bill represented as 12,000 kWh. Count the physical consumption once; use the other documents as evidence. Adding bill, meter and import quantities would count the same event repeatedly.
Make an evidence map with a canonical event identity, document reference, facility, covered dates, quantity/unit, origin and review decision. Keep original documents and extraction notes separate. A utility charge in money is not a quantity of electricity; it may include prices, tax or fees. A timestamp showing when a file was imported does not establish the consumption period. Different record keys do not prove different consumption, and matching keys do not replace a human check of the actual event.
The inspected MurrCloud Carbon foundation models facilities, periods, purchased-electricity activities, evidence, factor versions and finalized calculations. Its canonical source-system/source-key constraint can stop reusing an identical key, but a duplicate imported under another key still needs review. Required evidence review and input checks control workflow; they do not guarantee source authenticity, full coverage or automatic reconciliation with every ERP document. The addon installs no live emission factors. Use the printed worksheet as the default exercise; any software demonstration requires an instructor-approved isolated environment and appropriate Carbon roles. In such a lab, label both activity and factor Synthetic demo; never mix teaching inputs with operational records.
Work through the lesson
- Write W's facility, month, activity, boundary, method and exclusions before copying a number.
- Map W-BILL-101, W-METER-101 and W-IMPORT-101 to one canonical consumption event; distinguish primary source, corroboration and duplicate representation.
- Record one check the software can enforce and one question that still requires source review.
Teaching evidence
- COMMON-01
- All organizations, facilities, reviewers, quantities and factors below are fictional teaching data. Company: Academy Workshop. Contacts, if needed, use reviewer@example.invalid only. W and E are separate cases; never add their consumption. Use one English text submission. No real records, credentials, account connections or external writes are needed.
- BOUNDARY-01
- For each case include only purchased grid electricity consumed at its single stated facility in its stated month. Exclude transport, fuels, product manufacturing attribution, employee travel, other sites and other months. Do not claim total business emissions, product footprint, carbon neutrality, a regulatory filing or compliance. Country/region labels are matching metadata for invented examples, not a claim about actual grid factors.
- W-FACILITY / W-PERIOD
- Worked case W: Academy Workshop's Training-West facility, country GB, region Training-West. Period 2027-01-01 through 2027-01-31 inclusive. Activity date 2027-01-31. Boundary and method are BOUNDARY-01 and FACTOR-POLICY-01. No on-site generation, export, meter replacement or other electricity activity in W.
- W-BILL-101
- Invented electricity statement for Training-West and January 2027 reports 12 MWh consumed. Original source identity is source_system training-utility, source_key W-CONSUMPTION-101. Treat this as one consumption event; no monetary charge is used as activity data.
- W-METER-101 / W-IMPORT-101
- The corresponding fictional meter log starts at 80,000 kWh and ends at 92,000 kWh with no rollover, export or adjustment. W-IMPORT-101 repeats the same January bill as 12,000 kWh. The log corroborates W-BILL-101; the import is a duplicate representation, not additional consumption.
Try it
Create a plain-text W evidence register with reference, event identity, dates, quantity/unit, role and include/corroborate/duplicate decision. No uploads or live accounts are required.
Self-check
- Which exact question does the purchased-electricity boundary answer, and which company-wide claim does it leave unsupported?
- What evidence would distinguish a second physical event from the same bill imported with a new technical key?
Write your reasoning before comparing it with the worked example. Use the cited records to explain a decision, rather than relying on a summary or confidence score.
Training method: fictional records and a text worksheet. No production ERP access, live marketplace or payment account, paid OCR call or external upload is required.